ELECTRONIC CLASSROOM FURNITURE SYSTEMS, L.C.
A LIMITED LIABILITY COMPANY
PRICE LIST #111
January 2, 2006
ZONE #1
7/3 ELECTRICAL HARNESS SYSTEMS
This Electrical Harness System is a 3-circuit, 3-phase, 20-amp system that is
fully UL Recognized.
Each workstation should be fitted with one Triplex Power Module with three
Simplexes and an Interconnecting Cable. One Power Feed should be used for
up to 15 workstations.
This system is available with In-Line Surge Protectors. One #EILSP is
required for each circuit. Use a suffix -1, -2, -3 to identify the
circuits.
POWER FEEDS
MODEL # | DESCRIPTION | * | UNIT LIST PRICE |
ESPF-84 | STARTER POWER FEED - WALL OR FLOOR - 84" | 80.00 | |
ECPF-144 | STARTER POWER FEED - CEILING - 144" | 117.00 | |
ESPF-P1-15 | STARTER POWER FEED - 15 AMP PLUG, CIRCUIT 1 - 72" | * | 116.00 |
ESPF-P1-20 | STARTER POWER FEED - 20 AMP PLUG, CIRCUIT 1 - 72" | * | 116.00 |
* Can only be used with Model # ES-1 Simplex Receptacles.
INTERCONNECTING CABLES
MODEL # | DESCRIPTION | UNIT LIST PRICE |
EIC-S11 | SHORT - 11" | 66.00 |
EIC-S14 | SHORT - 14" | 66.00 |
EIC-S17 | SHORT - 17" | 66.00 |
EIC-S20 | SHORT - 20" | 66.00 |
EIC-S23 | SHORT - 23" | 66.00 |
EIC-S26 | SHORT - 26" | 66.00 |
EIC-S29 | SHORT - 29" | 66.00 |
EIC-S32 | SHORT - 32" | 66.00 |
EIC-S35 | SHORT - 35" | 66.00 |
EIC-S38 | SHORT - 38" | 66.00 |
EIC-L41 | LONG - 41" | 86.00 |
EIC-L44 | LONG - 44" | 86.00 |
EIC-L47 | LONG - 47" | 86.00 |
EIC-L50 | LONG - 50" | 86.00 |
EIC-L53 | LONG - 53" | 86.00 |
EIC-L56 | LONG - 56" | 86.00 |
EIC-L59 | LONG - 59" | 86.00 |
EIC-L62 | LONG - 62" | 86.00 |
EIC-L65 | LONG - 65" | 86.00 |
EIC-L71 | LONG - 71" | 86.00 |
EIC-L74 | LONG - 74" | 86.00 |
POWER MODULES
MODEL # | DESCRIPTION | UNIT LIST PRICE |
EPM | POWER MODULE TRIPLEX | 24.00 |
EPM-DS | POWER MODULE SIXPLEX W/MB | 28.00 |
SIMPLEX RECEPTACLES
MODEL # | DESCRIPTION | UNIT LIST PRICE |
ES-1 | SIMPLEX RECEPTACLE - CIRCUIT #1 | 8.00 |
ES-2 | SIMPLEX RECEPTACLE - CIRCUIT #2 | 8.00 |
ES-3 | SIMPLEX RECEPTACLE - CIRCUIT #IG | 9.00 |
8/4 ELECTRICAL HARNESS SYSTEMS
This Electrical Harness System is a 4-circuit, 3-phase, 20-amp system that is
fully UL Recognized.
Each workstation should be fitted with one Fourplex Power Module with two
Duplexes and an Interconnecting Cable. One Power Feed should be used
for up to 22 workstations.
POWER FEEDS
MODEL # | DESCRIPTION | * | UNIT LIST PRICE |
ESPF/8-84 | STARTER POWER FEED - WALL OR FLOOR - 84" | 85.00 | |
ECPF/8-144 | STARTER POWER FEED - CEILING - 144" | 121.00 | |
ESPF/8-P1-15-R | STARTER POWER FEED - 15 AMP PLUG, CIRCUIT 1 - 72" (RIGHT) | * | 116.00 |
ESPF/8-P1-15-S | STARTER POWER FEED - 15 AMP PLUG, CIRCUIT 1 - 72" (STRAIGHT) | * | 116.00 |
ESPF/8-P1-20-S | STARTER POWER FEED - 20 AMP PLUG, CIRCUIT 1 - 72" (RIGHT) | * | 116.00 |
ESPF/8-P1-20-S | STARTER POWER FEED - 20 AMP PLUG, CIRCUIT 1 - 72" (STRAIGHT) | * | 116.00 |
* Can only be used with Model # ED-1 Duplex Receptacles.
INTERCONNECTING CABLES
MODEL # | DESCRIPTION | UNIT LIST PRICE |
EIC/8-S11 | SHORT - 11" | 66.00 |
EIC/8-S14 | SHORT - 14" | 66.00 |
EIC/8-S17 | SHORT - 17" | 66.00 |
EIC/8-S20 | SHORT - 20" | 66.00 |
EIC/8-S23 | SHORT - 23" | 66.00 |
EIC/8-S26 | SHORT - 26" | 66.00 |
EIC/8-S29 | SHORT - 29" | 66.00 |
EIC/8-S32 | SHORT - 32" | 66.00 |
EIC/8-S35 | SHORT - 35" | 66.00 |
EIC/8-S38 | SHORT - 38" | 66.00 |
EIC/8-L41 | LONG - 41" | 86.00 |
EIC/8-L44 | LONG - 44" | 86.00 |
EIC/8-L47 | LONG - 47" | 86.00 |
EIC/8-L50 | LONG - 50" | 86.00 |
EIC/8-L53 | LONG - 53" | 86.00 |
EIC/8-L56 | LONG - 56" | 86.00 |
EIC/8-L59 | LONG - 59" | 86.00 |
EIC/8-L62 | LONG - 62" | 86.00 |
EIC/8-L65 | LONG - 65" | 86.00 |
EIC/8-L71 | LONG - 71" | 86.00 |
EIC/8-L74 | LONG - 74" | 86.00 |
POWER MODULE
MODEL # | DESCRIPTION | UNIT LIST PRICE |
EPM/8 | POWER MODULE FOURPLEX | 35.00 |
DUPLEX RECEPTACLES
MODEL # | DESCRIPTION | UNIT LIST PRICE |
ED-1 | DUPLEX RECEPTACLE - CIRCUIT #1 | 11.00 |
ED-1-IG | DUPLEX RECEPTACLE - CIRCUIT #1-IG | 11.00 |
ED-2-IG | DUPLEX RECEPTACLE - CIRCUIT #2-IG | 11.00 |
ED-3-IG | DUPLEX RECEPTACLE - CIRCUIT #3-IG | 11.00 |
ED-4-IG | DUPLEX RECEPTACLE - CIRCUIT #4-IG | 11.00 |
ELECTRICAL COMPONENTS AND DATA WIRING
DATA POWER SPHERES
The Power Spheres are fitted with 2 outlets, a 6' cord and two RJ-45 AMP connectors.
MODEL # | DESCRIPTION | * | UNIT LIST PRICE |
EBLANKS | BLANK SPHERE HALF | * | 44.00 |
EDATAS | DATA SPHERE HALF - 2 RJ-45 CONNECTORS | * | 73.00 |
EPOWS | POWER SPHERE HALF - 2 OUTLETS | * | 85.00 |
* Use the model "-DPS" after Worksurface model # you use the Data/Power Sphere in. Then use "-L" for Left Side Position, "-C" for Center Position, "-R" for Right Side Position. Contact factory for other positions.
POWER STRIPS
The Power Strip has 4 outlets and a 9' cord to plug into standard outlet.
The Power Strip is to be used for single and double station functions only.
UL Listed.
Underwriters Laboratory, Inc., does not permit the "daisy chaining" of
Power
Strips.
MODEL # | DESCRIPTION | UNIT LIST PRICE |
EPS | 4 OUTLET, 9' CORD | 73.00 |
EPS-SRG | 6 OUTLET, 9' CORD, SURGE PROTECTION | 166.00 |
POWER/DATA POP-UP UNIT
MODEL # | DESCRIPTION | * | UNIT LIST PRICE |
POP | POWER/DATA POP-UP UNIT | * | 198.00 |
* Use the model "-POP" after Worksurface model # you use the Pop-Up Unit in. Then use "-L" for Left Side Position, "-C" for Center Position, "-R" for Right Side Position. Contact factory for other positions.
END CAP EXTENSIONS
CONVENIENCE OUTLET EXTENSION
The Convenience Outlet Extension has a pre-mounted Simplex on the plastic end cap of either Spreader with wiring and plug. The plug inserts into one of the outlets in the Power Module in the Raceway. Please state whether the outlet will be placed in an Upper or Lower Spreader.
MODEL # | DESCRIPTION | UNIT LIST PRICE |
COE | CONVENIENCE OUTLET EXTENSION | 39.00 |
COE-2 | DOUBLE CONVENIENCE OUTLET EXTENSION | 76.00 |
DATA LINKAGE EXTENSION
The Data Linkage Extension has pre-mounted RJ-45, RJ-11, or other networking
connector on the plastic end cap of either Spreader. The plug inserts into
the back of the CPU or data drop located in the Raceway depending upon the
network wiring configuration. Verify type of
connector, cut-out size, and wire length. Wire is CAT 5. Verify type of
Cat 5.
MODEL # | DESCRIPTION | UNIT LIST PRICE |
DLE45 | DATA LINKAGE - RJ45 | 60.00 |
DLE45-2 | DOUBLE DATA LINKAGE - RJ45 | 118.00 |
DLE11 | DATA LINKAGE - RJ11 | 60.00 |
DLE11-2 | DOUBLE DATA LINKAGE - RJ11 | 118.00 |
DLEUSB | DATA LINKAGE - USB | 88.00 |
DLEUSB-2 | DOUBLE DATA LINKAGE - USB | 174.00 |
DLE45/COE-S | DATA LINKAGE/CONVENIENCE OUTLET - RJ45 (SHORT) | 96.00 |
DLE45/COE-L | DATA LINKAGE/CONVENIENCE OUTLET - RJ45 (LONG) | 104.00 |
HEADPHONE EXTENSION
The Headphone Extension has a pre-mounted 1/8" jack on the plastic end cap of the
Top Spreader with wiring and a 1/8" plug. The plugs insert into the audio
ports of the computer or into a sound box. If a different size jack is
required, please state and add 25%.
MODEL # | DESCRIPTION | UNIT LIST PRICE |
HE-1 | HEADPHONE OR MICROPHONE EXTENSION ONE, JACK/PLUG | 33.00 |
HME-2 | HEADPHONE OR MICROPHONE EXTENSION TWO, JACK/PLUG | 64.00 |
HME-3 | HEADPHONE OR MICROPHONE EXTENSION THREE, JACK/PLUG | 97.00 |
HME-4 | HEADPHONE OR MICROPHONE EXTENSION FOUR, JACK/PLUG | 130.00 |
SHROUDS
Shrouds are used to cover wiring being chased from the floor to the underside of
the Raceway.
Small quantities are subject to availability.
MODEL # | DESCRIPTION | UNIT LIST PRICE |
SHROUD #1 | VERTICAL WIRE SHROUD | CALL FACTORY FOR PRICING |
SHROUD #2 | HORIZONTAL WIRE SHROUD | CALL FACTORY FOR PRICING |